Search

Search Results

Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.
Reliable, comfortable and energy-efficient - that’s how vacuum drying works today. Separately adjustable and directly heated thermoshelves ensure precise temperature control and, thanks to the digital pressure control, the chamber load is not only dried at high speed but also extremely gently in our Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.

VO101 Model

Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.
VO101 Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.

VO49 Model

Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.
VO49 Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.

VO29 Model

Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.
VO29 Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.
If vacuum ovens are applied to dry large amounts of powder and granulate, the occurring volume expansion of the heated atmosphere in the interior sets a physically defined end to the capability of the vacuum pump to transfer humidity.
The result: Heat transfer and steam removal come out of balance and the samples dry extremely slow or even simmer in their own juice. Just opening the door of the vacuum oven to ventilate the interior would be the worst possible solution of this problem. For this reason, Memmert as the first m
Vacuum oven technology explained by a veteran expert. Read about its use, application, technical specialties and more in this Memmert exclusive interview.
Memmert: Hello Mr. Bayer, you have been part of the Memmert family for 35 years and know the product portfolio like the back of your hand – or maybe even better! You have already told us that the VO vacuum oven is one of your favorite products. Why?Heinz Bayer:
A vacuum drying oven offers unique advantages. In this article you will learn more about its benefits.
The heating and drying ovens sector finds several laboratory ovens in use. Often these have special purpose given the applications they are dealing with. For users involved in application sectors such as the following will find a vacuum oven most useful: Pharmaceutical industry: p
Microdul AG in Switzerland is a recognised expert in the miniaturisation of electronic circuits, especially for medical technology. The company uses a Memmert vacuum drying oven VO 400 for degassing epoxy resins as standard equipment in the manufacture of electronic modules, in order to remove voids before curing.
Manufacturing process for electronic modules The example module, about 2.5 cm in diameter and only 1.4 mm thick, contains seven integrated circuits (microchips) as the main components. The electronic module is intended as a medical device for human implantation and therefore must fulfil the
Precision in the micrometre range. 100 % reliability. In the production of artificial hearts by Berlin Heart, the highest standards of quality apply for all processes. The modules for the ventricular assist device EXCOR® are dried in a Memmert drying oven and vacuum oven.
Artificial hearts, so-called ventricular assist devices or VADs, are used predominantly when waiting times for a heart transplant need to be bridged. Berlin is one of the most important international centres for cardiological research. This is where Emil Bücherl worked, one of the first surgeons to
Environmental protection is part of Memmert's corporate philosophy. Wide range of energy-efficient Peltier-cooled incubators and climatic chambers.
Ecological Responsibility Sustainability is firmly anchored in our corporate strategy. With energy-efficient and climate-friendly laboratory equipment, Memmert continues to push the development of the GreenLab.